Choose the right load class
AS/NZS 3996:2019 Load Classifications
Note 1: Classifications are based on AS/NZS 3996:2019. Nominal wheel loads are provided as a guide only. The final selection of the appropriate load class remains the responsibility of the project’s consulting engineer.
Note 2: Hyvol grates are tested to AS/NZS 3996:2019. For structural applications, our Class B and Class C units typically satisfy the requirements for AS/NZS 1170.1 Type F & G activities. Contact our team for specific structural load certifications.
Choose the right catchment area
To specify the correct Hyvol system, ensure your selected channel meets both the structural load requirement (AS/NZS 3996) and the hydraulic catchment capacity below:
Hydraulic Capacity & Catchment Selection Guide
Use the guide below to match your project's total surface catchment area to the correct Hyvol drainage system.
Area
Rate
System
Technical Specifier Note: Catchment capacities are indicative only and based on a conservative average rainfall intensity of 100 mm/hr. For projects with steep gradients, specialized continuous run-off lengths, or strict local council overland flow requirements, please contact our engineering team for custom hydraulic calculations and sizing verification.
Specifications,
Installation & CAD
Specify With Confidence
Every infrastructure project demands rigorous engineering data. Download the complete technical specification sheets for the HYVOL® range, featuring, material tolerances, and AS/NZS 3996:2019 compliance certifications.
Design It Right
Accelerate your design workflow and eliminate manual take-off errors. Download our verified DWG drawing blocks to drop HYVOL® channel drainage directly into your site plans. Each smart CAD block is pre-programmed with data attributes -allowing you to automatically extract an accurate Bill of Materials (BOM) and total drain linear-meter quantities directly into your project schedules.
HY 150 B — Smart CAD Block (.DWG)
HY 200 B — Smart CAD Block (.DWG)
HY 200 C — Smart CAD Block (.DWG)
HY 300 C — Smart CAD Block (.DWG)
Full HYVOL® Suite — Combined CAD Library (.DWG / .ZIP)
Supply Chain & Availability Certainty
Because Hyvol is 100% locally manufactured in New Zealand and stocked nationwide via our merchant partners - including Hynds, PlaceMakers, ITM, Plumbing World and Atlas Concrete - specifiers can guarantee clients short material lead times and uninterrupted regional supply chain security.
Get The Installation Right
Long-term performance relies on good site execution. Our installation framework aligns with New Zealand Building Codes and regional council asset protection standards to ensure a seamless, compliant hand-over.
-
1.
SAFETY & UTILITIES
Always locate underground services via BeforeU Dig prior to trenching. -
2.
ENCASEMENT
Use a minimum of 20MPa structural concrete around the channel base and sides. -
4.
FLUSH FINISH
Ensure the surrounding pavement is finished completely flush with the top edge of the HYVOL® grate to eliminate trip hazards. -
5.